Critical Infrastructure
HVAC and Mechanical Infrastructure Systems
Air conditioning is the discipline that directly determines both availability and energy cost in data centre and server room projects. ONGSEC takes on the entire mechanical infrastructure — from heat load calculation to equipment …
Scope of service
What we do under this heading
Heat Load Calculation and Airflow Analysis
Separate calculation of IT equipment heat load, lighting, occupancy and building envelope gains; Rack-based density ma…
VIEWPrecision Cooling Systems
Data centre cooling must not be confused with comfort cooling: it requires a high sensible heat ratio, continuous oper…
VIEWClose-Coupled and High-Density Cooling
InRow cooling units for targeted cooling of high-density rack rows; Rear-door heat exchanger applications…
VIEWChillers and Distribution Pipework
Chiller selection: air-cooled, water-cooled and free-cooling models; Dry cooler, cooling tower and adiabatic pre-cooli…
VIEWFree Cooling and Energy Efficiency
Air-side and water-side free cooling feasibility and annual savings modelling; Adiabatic / evaporative cooling applica…
VIEWAir Management and Containment
Design, fabrication and installation of hot or cold aisle containment systems; Ceiling panels and automatically openin…
VIEWHumidity Control and Air Quality
Humidification (steam / ultrasonic) and dehumidification systems, central humidity control strategy; Balancing electro…
VIEWBuilding Mechanical and Ventilation Systems
VRF/VRV, split and fan coil systems for administrative area conditioning; Air handling unit (AHU) selection, fresh air…
VIEWHeat Load Calculation and Airflow Analysis
- Separate calculation of IT equipment heat load, lighting, occupancy and building envelope gains
- Rack-based density map and hot spot risk analysis
- CFD (computational fluid dynamics) simulation to model airflow and temperature distribution
- Producing a real-condition map of existing rooms via thermal imaging and sensor measurement
- Delta-T analysis and identification of bypass/recirculation losses
- Verifying temperature behaviour under redundancy scenarios (one unit out of service)
Precision Cooling Systems
Data centre cooling must not be confused with comfort cooling: it requires a high sensible heat ratio, continuous operation and a narrow temperature–humidity band. In our installations, room-based precision cooling solutions are selected according to the project.
- Downflow (raised floor supply) and upflow layout options
- Direct expansion (DX) air-cooled and water-cooled units
- Chilled water CRAH units with valve and actuator automation
- EC fan technology, variable speed control and pressure/temperature-based capacity modulation
- Rotation between unit groups, standby unit activation and group control
- N+1 / 2N unit redundancy and concurrent maintainability scenarios
Close-Coupled and High-Density Cooling
- InRow cooling units for targeted cooling of high-density rack rows
- Rear-door heat exchanger applications
- Closed-loop cabinet solutions and high-density islands
- Liquid cooling: direct-to-chip cold plates and coolant distribution units (CDU)
- Assessment of immersion cooling infrastructure and derivation of facility requirements
- Engineering 30–100 kW+ density scenarios for AI and high-performance computing (HPC) racks
- Hybrid solutions: managing air and liquid cooling together in the same hall
Chillers and Distribution Pipework
- Chiller selection: air-cooled, water-cooled and free-cooling models
- Dry cooler, cooling tower and adiabatic pre-cooling alternatives
- Primary/secondary pump groups, variable flow system design and redundant pump architecture
- Pipework engineering, diameter calculation, expansion, insulation and vibration management
- Glycol ratio, freeze protection, water treatment and corrosion control
- Buffer tanks to provide cooling autonomy until the generator picks up load
- Redundant ring main pipework and isolation valve strategy for concurrent maintainability
Free Cooling and Energy Efficiency
- Air-side and water-side free cooling feasibility and annual savings modelling
- Adiabatic / evaporative cooling applications and water consumption assessment
- Setting economiser mode transition thresholds from local climate data
- Setpoint optimisation against ASHRAE recommended and allowable operating envelopes
- Increasing chiller efficiency by raising chilled water temperature
- PUE measurement, monitoring and improvement roadmap
- Assessment of heat recovery scenarios contributing to office or workshop heating
Air Management and Containment
- Design, fabrication and installation of hot or cold aisle containment systems
- Ceiling panels and automatically opening containment elements compatible with the fire scenario
- Preventing air leakage with blanking panels, side panels and floor brush grommets
- Perforated tile placement and flow optimisation in raised floors
- Room pressure balance, leakage rate and management of door and transit effects
- Reducing the impact of cable density on airflow, under-floor tidying
Humidity Control and Air Quality
- Humidification (steam / ultrasonic) and dehumidification systems, central humidity control strategy
- Balancing electrostatic discharge (ESD) and condensation risks
- Determining filter classes (G4 / F7 / H13) and filter replacement plan
- Corrosive gas monitoring (ISA 71.04 classification) and chemical filtration where required
- Control of dust, particulates and outdoor air quality at the data centre intake
Building Mechanical and Ventilation Systems
- VRF/VRV, split and fan coil systems for administrative area conditioning
- Air handling unit (AHU) selection, fresh air and heat recovery units
- Dedicated conditioning solutions for control rooms, laboratories and test areas
- Battery room ventilation and hydrogen dilution calculation
- Generator room fresh air, exhaust and radiator air discharge engineering
- Fire-scenario-linked dampers, pressurisation and smoke extraction systems
- Kitchen/workshop exhaust and industrial ventilation applications
Monitoring, Automation, Maintenance and Optimisation
- BMS/DCIM integration of mechanical systems (Modbus, BACnet, SNMP)
- Programming setpoints, alarm thresholds and automatic standby activation scenarios
- Continuous monitoring and reporting of energy and cooling performance indicators
- Periodic maintenance programme: filters, belts, condensate drains, refrigerant charge, leak testing
- Compressor and fan vibration analysis, predictive maintenance via thermal imaging
- Efficiency audit (retro-commissioning) and improvement works on existing systems
- Spare parts stock planning and rapid response agreements for critical equipment
On this page
- Heat Load Calculation and Airflow Analysis
- Precision Cooling Systems
- Close-Coupled and High-Density Cooling
- Chillers and Distribution Pipework
- Free Cooling and Energy Efficiency
- Air Management and Containment
- Humidity Control and Air Quality
- Building Mechanical and Ventilation Systems
- Monitoring, Automation, Maintenance and Optimisation
Typical deliverables
- Heat load calculation
- CFD report
- Equipment selection file
- Commissioning and performance test report
Let us define the scope together
A short discovery call is enough to identify the slice of this portfolio you actually need.
Request a quoteRelated services
What usually runs alongside this
Data Centre Consultancy, Feasibility and Design
We shape data centre investment from feasibility to tender documentation with independent engineering judgement.
EXPLORE Critical InfrastructureData Centre Construction and Turnkey Delivery
Turnkey data centre construction from shell and core to commissioning, with all disciplines under one project management.
EXPLORE Critical InfrastructureExtra-Low Voltage Systems and Electrical Engineering
From structured cabling to CCTV and access control, from fire detection to building automation and electrical engineering.
EXPLOREGet started
Let us talk about your project.
The first meeting is a discovery session, not a sales pitch. You are also welcome to evaluate our capability directly through a short pilot or proof of concept (PoC) in your own environment.