Air conditioning is the discipline that directly determines both availability and energy cost in data centre and server room projects. ONGSEC takes on the entire mechanical infrastructure — from heat load calculation to equipment …

ASHRAE TC 9.9CFD simulationFree coolingPUE measurementLiquid cooling
01

Heat Load Calculation and Airflow Analysis

  • Separate calculation of IT equipment heat load, lighting, occupancy and building envelope gains
  • Rack-based density map and hot spot risk analysis
  • CFD (computational fluid dynamics) simulation to model airflow and temperature distribution
  • Producing a real-condition map of existing rooms via thermal imaging and sensor measurement
  • Delta-T analysis and identification of bypass/recirculation losses
  • Verifying temperature behaviour under redundancy scenarios (one unit out of service)
02

Precision Cooling Systems

Data centre cooling must not be confused with comfort cooling: it requires a high sensible heat ratio, continuous operation and a narrow temperature–humidity band. In our installations, room-based precision cooling solutions are selected according to the project.

  • Downflow (raised floor supply) and upflow layout options
  • Direct expansion (DX) air-cooled and water-cooled units
  • Chilled water CRAH units with valve and actuator automation
  • EC fan technology, variable speed control and pressure/temperature-based capacity modulation
  • Rotation between unit groups, standby unit activation and group control
  • N+1 / 2N unit redundancy and concurrent maintainability scenarios
03

Close-Coupled and High-Density Cooling

  • InRow cooling units for targeted cooling of high-density rack rows
  • Rear-door heat exchanger applications
  • Closed-loop cabinet solutions and high-density islands
  • Liquid cooling: direct-to-chip cold plates and coolant distribution units (CDU)
  • Assessment of immersion cooling infrastructure and derivation of facility requirements
  • Engineering 30–100 kW+ density scenarios for AI and high-performance computing (HPC) racks
  • Hybrid solutions: managing air and liquid cooling together in the same hall
04

Chillers and Distribution Pipework

  • Chiller selection: air-cooled, water-cooled and free-cooling models
  • Dry cooler, cooling tower and adiabatic pre-cooling alternatives
  • Primary/secondary pump groups, variable flow system design and redundant pump architecture
  • Pipework engineering, diameter calculation, expansion, insulation and vibration management
  • Glycol ratio, freeze protection, water treatment and corrosion control
  • Buffer tanks to provide cooling autonomy until the generator picks up load
  • Redundant ring main pipework and isolation valve strategy for concurrent maintainability
05

Free Cooling and Energy Efficiency

  • Air-side and water-side free cooling feasibility and annual savings modelling
  • Adiabatic / evaporative cooling applications and water consumption assessment
  • Setting economiser mode transition thresholds from local climate data
  • Setpoint optimisation against ASHRAE recommended and allowable operating envelopes
  • Increasing chiller efficiency by raising chilled water temperature
  • PUE measurement, monitoring and improvement roadmap
  • Assessment of heat recovery scenarios contributing to office or workshop heating
06

Air Management and Containment

  • Design, fabrication and installation of hot or cold aisle containment systems
  • Ceiling panels and automatically opening containment elements compatible with the fire scenario
  • Preventing air leakage with blanking panels, side panels and floor brush grommets
  • Perforated tile placement and flow optimisation in raised floors
  • Room pressure balance, leakage rate and management of door and transit effects
  • Reducing the impact of cable density on airflow, under-floor tidying
07

Humidity Control and Air Quality

  • Humidification (steam / ultrasonic) and dehumidification systems, central humidity control strategy
  • Balancing electrostatic discharge (ESD) and condensation risks
  • Determining filter classes (G4 / F7 / H13) and filter replacement plan
  • Corrosive gas monitoring (ISA 71.04 classification) and chemical filtration where required
  • Control of dust, particulates and outdoor air quality at the data centre intake
08

Building Mechanical and Ventilation Systems

  • VRF/VRV, split and fan coil systems for administrative area conditioning
  • Air handling unit (AHU) selection, fresh air and heat recovery units
  • Dedicated conditioning solutions for control rooms, laboratories and test areas
  • Battery room ventilation and hydrogen dilution calculation
  • Generator room fresh air, exhaust and radiator air discharge engineering
  • Fire-scenario-linked dampers, pressurisation and smoke extraction systems
  • Kitchen/workshop exhaust and industrial ventilation applications
09

Monitoring, Automation, Maintenance and Optimisation

  • BMS/DCIM integration of mechanical systems (Modbus, BACnet, SNMP)
  • Programming setpoints, alarm thresholds and automatic standby activation scenarios
  • Continuous monitoring and reporting of energy and cooling performance indicators
  • Periodic maintenance programme: filters, belts, condensate drains, refrigerant charge, leak testing
  • Compressor and fan vibration analysis, predictive maintenance via thermal imaging
  • Efficiency audit (retro-commissioning) and improvement works on existing systems
  • Spare parts stock planning and rapid response agreements for critical equipment

Typical deliverables

  • Heat load calculation
  • CFD report
  • Equipment selection file
  • Commissioning and performance test report